As a CREIA member, Central Valley Inspection
subscribes to the CREIA Standards of Practice:
Residential Standards - Four or Fewer Units
- Originally Adopted September 13, 1983
- Revised November 1, 1996
- Revised April 15, 1999
- Revised July 12, 2003
- Revised April 15, 2006 — Effective July 1, 2006
Note: Italicized words in this document are
defined in the Glossary of Terms.
Table of Contents
I. Definitions and Scope
II. Standards of Practice
1. Foundation, Basement, and Under-floor Areas
2. Exterior
3. Roof Covering
4. Attic Areas and Roof Framing
5. Plumbing
6. Electrical
7. Heating and Cooling
8. Fireplaces and Chimneys
9. Building Interior
III. Limitations, Exceptions and
Exclusions
IV. Glossary of Terms
I. Definitions and Scope
These Standards of Practice provide guidelines for a real estate
inspection and define certain terms relating to these
inspections. Italicized words in these Standards are
defined in Part IV, Glossary of Terms.
- A. A real estate inspection is a
survey and basic operation of the systems and
components of a building which can be reached,
entered, or viewed without difficulty, moving obstructions, or
requiring any action which may result in damage to the property or
personal injury to the Inspector. The purpose of the
inspection is to provide the Client with information regarding
the general condition of the building(s). Cosmetic
and aesthetic conditions shall not be considered.
- B. A real estate inspection report
provides written documentation of material defects discovered in the
inspectedbuilding’ssystems and components which,
in the opinion of the Inspector, are safety hazards,
are not functioning properly, or appear to be at the ends
of their service lives. The report may include the Inspector's
recommendations for correction or further evaluation.
- C. Inspections performed in accordance
with these Standards of Practice are not technically exhaustive
and shall apply to the primary building and its associated
primary parking structure.
II. Standards of Practice
A real estate inspection includes the readily accessible
systems and components or a representative number
of multiple similar components listed in Sections 1 through 9
subject to the limitations, exceptions, and exclusions in
Part III.
1. Foundation, Basement, and Under-floor
Areas
A. Items to be inspected:
- Foundation system
- Floor framing system
- Under-floor ventilation
- Foundation anchoring and cripple wall bracing
- Wood separation from soil
- Insulation
B. The inspector is not required to:
- Determine size, spacing, location, or adequacy of
foundation bolting/bracing components or reinforcing
systems
- Determine the composition or energy rating of
insulation materials
2. Exterior
A. Items to be inspected:
- Surface grade directly adjacent to the buildings
- Doors and windows
- Attached decks, porches, patios, balconies, stairways, and
their enclosures
- Wall cladding and trim
- Portions of walkways and driveways that are adjacent to the
buildings
B. The inspector is not required to:
- Inspect door or window screens, shutters, awnings,
or security bars
- Inspect fences or gates or operate
automated door or gate openers or their safety devices
- Use a ladder to inspectsystems or components
3. Roof Covering
A. Items to be inspected:
- Covering
- Drainage
- Flashings
- Penetrations
- Skylights
B. The inspector is not required to:
- Walk on the roof surface if in the opinion of the
Inspector there is risk of damage or a hazard to
the Inspector
- Warrant or certify that roof systems, coverings, or
components are free from leakage
4. Attic Areas and Roof Framing
A. Items to be inspected:
- Framing
- Ventilation
- Insulation
B. The inspector is not required to:
- Inspect mechanical attic ventilation systems
or components
- Determine the composition or energy rating of
insulation materials
5. Plumbing
A. Items to be inspected:
- Water supply piping
- Drain, waste, and vent piping
- Faucets and fixtures
- Fuel gas piping
- Water heaters
- Functional flow and functional drainage
B. The inspector is not required to:
- Fill any fixture with water, inspect
overflow drains or drain-stops, or evaluate backflow
devices, waste ejectors, sump pumps, or drain line
cleanouts
- Inspect or evaluate water temperature balancing
devices, temperature fluctuation, time to obtain hot water,
water circulation, or solar heating systems or
components
- Inspect whirlpool baths, steam showers, or sauna
systems or components
- Inspect fuel tanks or determine if the
fuel gas system is free of leaks
- Inspect wells or water treatment systems
6. Electrical
A. Items to be inspected:
- Service equipment
- Electrical panels
- Circuit wiring
- Switches, receptacles, outlets, and lighting fixtures
B. The inspector is not required to:
- Operate circuit breakers or circuit interrupters
- Remove cover plates
- Inspect de-icing systems or components
- Inspect private or emergency electrical supply
systems or components
7. Heating and Cooling
A. Items to be inspected:
- Heating equipment
- Central cooling equipment
- Energy source and connections
- Combustion air and exhaust vent systems
- Condensate drainage
- Conditioned air distribution systems
B. The inspector is not required to:
- Inspect heat exchangers or electric heating
elements
- Inspect non-central air conditioning units or
evaporative coolers
- Inspect radiant, solar, hydronic, or geothermal
systems or components
- Determine volume, uniformity, temperature, airflow,
balance, or leakage of any air distribution system
- Inspect electronic air filtering or humidity
control systems or components
8. Fireplaces and Chimneys
A. Items to be inspected:
- Chimney exterior
- Spark arrestor
- Firebox
- Damper
- Hearth extension
B. The inspector is not required to:
- Inspect chimney interiors
- Inspect fireplace inserts, seals, or gaskets
- Operate any fireplace or determine if a
fireplace can be safely used
9. Building Interior
A. Items to be inspected:
- Walls, ceilings, and floors
- Doors and windows
- Stairways, handrails, and guardrails
- Permanently installed cabinets
- Permanently installed cook-tops, mechanical range
vents, ovens, dishwashers, and food waste disposers
- Absence of smoke alarms
- Vehicle doors and openers
B. The inspector is not required to:
- Inspect window, door, or floor coverings
- Determine whether a building is secure
from unauthorized entry
- Operate or test smoke alarms or vehicle door safety
devices
- Use a ladder to inspect systems or components
III. Limitations, Exceptions and
Exclusions
A. The following are excluded from a real estate inspection:
- Systems or components of a building,
or portions thereof, which are not readily accessible, not
permanently installed, or not inspected due to
circumstances beyond the control of the Inspector or which
the Client has agreed or specified are not to be inspected
- Site improvements or amenities, including, but not limited to;
accessory buildings, fences, planters, landscaping, irrigation,
swimming pools, spas, ponds, waterfalls, fountains or their
components or accessories
- Auxiliary features of appliances beyond the
appliance’s basic function
- Systems or components, or portions thereof,
which are under ground, under water, or where the Inspector
must come into contact with water
- Common areas as defined in California Civil Code section 1351,
et seq., and any dwelling unit systems or components
located in common areas
- Determining compliance with manufacturers’ installation
guidelines or specifications, building codes, accessibility
standards, conservation or energy standards, regulations,
ordinances, covenants, or other restrictions
- Determining adequacy, efficiency, suitability, quality,
age, or remaining life of any building, system, or
component, or marketability or advisability of purchase
- Structural, architectural, geological, environmental,
hydrological, land surveying, or soils- related examinations
- Acoustical or other nuisance characteristics of any system
or component of a building, complex, adjoining
property, or neighborhood
- Conditions related to animals, insects, or other organisms,
including fungus and mold, and any hazardous, illegal, or controlled
substance, or the damage or health risks arising there from
- Risks associated with events or conditions of nature including,
but not limited to; geological, seismic, wildfire, and flood
- Water testing any building, system, or
component or determine leakage in shower pans, pools,
spas, or any body of water
- Determining the integrity of hermetic seals at
multi-pane glazing
- Differentiating between original construction or subsequent
additions or modifications
- Reviewing information from any third-party, including but not
limited to; product defects, recalls, or similar notices
- Specifying repairs/replacement procedures or estimating cost to
correct
- Communication, computer, security, or low-voltage systems
and remote, timer, sensor, or similarly controlled systems
or components
- Fire extinguishing and suppression systems and
components or determining fire
resistive qualities of materials or assemblies
- Elevators, lifts, and dumbwaiters
- Lighting pilot lights or activating or operating any
system, component, or appliance that is
shut down, unsafe to operate, or does not respond
to normal user controls
- Operating shutoff valves or shutting down any
system or component
- Dismantling any system, structure, or component
or removing access panels other than those provided for homeowner
maintenance
B. The Inspector may, at his or her discretion:
- Inspect any building, system,
component, appliance, or improvement not included or
otherwise excluded by these Standards of Practice. Any such
inspection shall comply with all other provisions of these
Standards.
- Include photographs in the written report or take photographs
for Inspector’s reference without inclusion in the written
report. Photographs may not be used in lieu of written
documentation.
IV - Glossary of Terms
Note: All definitions apply to derivatives of these
terms when italicized in the text.
- Appliance: An item such as an oven, dishwasher,
heater, etc. which performs a specific function
- Building: The subject of the inspection
and its primary parking structure
- Component: A part of a system,
appliance, fixture, or device
- Condition: Conspicuous state of being
- Determine: Arrive at an opinion or conclusion
pursuant to a real estate inspection
- Device: A component designed to
perform a particular task or function
- Fixture: A plumbing or electrical component
with a fixed position and function
- Function : The normal and characteristic
purpose or action of a system, component, or
device
- Functional Drainage: The ability to empty a
plumbing fixture in a reasonable time
- Functional Flow: The flow of the water supply
at the highest and farthest fixture from the building
supply shutoff valve when another fixture is used
simultaneously
- Inspect: Refer to Part I,
“Definition and Scope”, Paragraph A
- Inspector: One who performs a real estate
inspection
- Normal User Control: Switch or other device
that activates a system or component and is
provided for use by an occupant of a building
- Operate: Cause a system, appliance,
fixture, or device to function using
normal user controls
- Permanently Installed: Fixed in place, e.g.
screwed, bolted, nailed, or glued
- Primary Building : A building that an
Inspector has agreed to inspect
- Primary Parking structure: A building
for the purpose of vehicle storage associated with the primary
building
- Readily Accessible: Can be reached, entered, or
viewed without difficulty, moving obstructions, or requiring any
action which may harm persons or property
- Real Estate Inspection: Refer to Part I,
“Definitions and Scope”, Paragraph A
- Representative Number: Example, an average of
one component per area for multiple similar components
such as windows, doors, and electrical outlets
- Safety Hazard: A condition that could
result in significant physical injury
- Shut Down: Disconnected or turned off in a way
so as not to respond to normal user controls
- System: An assemblage of various components
designed to function as a whole
- Technically Exhaustive: Examination beyond the
scope of a real estate inspection, which may require
disassembly, specialized knowledge, special equipment, measuring,
calculating, quantifying, testing, exploratory probing, research, or
analysis
|